PowerCube® Specifications

Dimensions:
H 214cm x W 214 x D 244cm (H 7ft x W 7ft x D 8ft)
Weight:
2000 Kg as shipped (~2 tons)
2500 Kg with fuel (~2.5 tons)
Fuel Cell:
Two (2) 4.4kW PEM stacks
Fuel Processor:
Proprietary NH3 cracker, thermal efficiency >85%
Power Conditioning:
Proprietary DC-DC converter, 96% efficient
Nominal Power:
1.2kW continuous output
Nominal Voltage:
48VDC/25A (version 120a), 24VDC/50A (version 120e)
System Cooling:
Twin closed-loop deionized water/glycol to external radiator
Fuel Specification:
Refrigeration-spec anhydrous ammonia (NH3)
Fuel Capacity:
500 Kg
Fuel Consumption:
0.7 Kg/hour on standard operating cycle
Refill Interval:
Monthly (unless fitted with external tank)
Routine Service:
Quarterly (NH3 and air filter change)
Lubrication:
None required
Stack Service Interval:
12 month
Operating Temp, min to max:
-5°C to 50° C (23° to 122° F)
Sound Level:
50 db(A) at 7m (23ft) under full load
Internal climate control:
22° to 28° C via free air cooling and variable-speed DC a/c
(Optional climate packs available for high altitude, high dust environment, high humidity, and extreme desert conditions)
Water production:
Approx 1 L/hr ± 0.5L (varies with local humidity)
Nitrogen output:
0.65 m3/hour (vented to atmosphere with moist air)
Installation
100% self-contained; placed directly from truck to pad
Operational within 1 hour via automated start
Electrical connector plate provided to customer specification
Other:
Proprietary high-efficiency air filtration system
GPS monitoring and control system for immediate customer feedback and global system security
Accommodates standard telecom equipment rack

Copyright Diverse Energy 2009